Homebridge plugin supporting Overkiz based platforms :
| Service code | Vendor | Product compatibility |
|---|---|---|
local |
Somfy local API | TaHoma, TaHoma Switch (configure local API) |
somfy_europe |
Somfy Europe | TaHoma, TaHoma Switch, Connexoon IO, Kit de connectivité Orange |
somfy_australia |
Somfy Australia | Connexoon RTS and other products in Australia |
somfy_north_america |
Somfy North America | TaHoma and other product in North America |
cozytouch |
Atlantic, Thermor, Sauter | Cozytouch |
flexom |
Bouygues | Flexom |
hi_kumo |
Hitachi | Hi hi_kumo |
rexel |
Rexel | Energeasy connectivité |
- Install homebridge using:
npm install -g homebridge - Install this plugin using:
npm install -g homebridge-tahoma - Update your configuration file. See bellow for a sample.
Minimal configuration sample:
{
"bridge": {
...
},
"description": "...",
"accessories": [],
"platforms":[
{
"platform": "Tahoma",
"name": "My TaHoma Box",
"service": "somfy_europe",
"user": "user@me.com",
"password": "MyPassw0rd",
}
]
}
Configuration parameters:
| Parameter | Type | Default | Note |
|---|---|---|---|
service |
String | 'somfy_europe' | optional, service name (see above) |
user |
String | null | mandatory, your service account username (or gateway PIN / IP address) |
password |
String | null | mandatory, your service account password (or API token) |
pollingPeriod |
Integer | 30 | optional, bridge polling period in seconds |
refreshPeriod |
Integer | 30 | optional, device states refresh period in minutes |
exclude |
String[] | [] | optional, protocol, ui, widget or device name to exclude |
exposeScenarios |
Boolean | false | optional, expose scenarios as HomeKit switches. Could also specify a list of string corresponding to scenarios names to expose |
devicesConfig |
Object[] | [] | optional list of device specific configuration (see below) |
Local API service is available on TaHoma and TaHoma switch gateways.
WARNING: Switching to local API will break your HomeKit configuration (automations) as local API device identifiers actually differs.
The current way to active the developer mode on your gateway is to described in the official-looking developer GitHub Somfy-Developer/Somfy-TaHoma-Developer-Mode:
- Open the TaHoma By Somfy application on your device.
- Navigate to the Configure the installation > Access the parameters of your TaHoma box in the application.
- Activate Developer Mode by tapping 7 times on the PIN of your gateway (like 2001-1234-5678) in a fast pace.
- The app will show you a dialog with T&Cs and once confirmed, you'll be offered a screen to generate the token.
- Configure the plugin service to Local API:
"service":"local"with PIN of your gateway asuserand the generated token aspassword.
Note you do not need to use the online API credentials service anymore as you'll be given the token right away in the app.
Please note the Activate developer mode button in My Account appears to be not available anymore as of 08/2026 and the developer.somfy.com domain does not exist either.
To use Local API you will have to:
- Activate
developer mode(www.somfy.com > My Account > Activate developer mode) - Generate API credentials at https://dev.duboc.pro/homebridge-tahoma
- Configure the plugin service to Local API:
"service":"local"
When using Local API service, please fill user with your gateway PIN number or IPv4 address and password with the token generated at step 2
For more information, browse https://developer.somfy.com/developer-mode
This option allows you to apply a specific configuation to device or group of device.
One configuration is composed of a key attribute containing device name, widget, uiClass, protocol or unique identifier and as many parameter depending of device type.
{
"key": "Bedroom door",
"param1": "value1"
...
}
| Alarm parameters | Type | Default | Note |
|---|---|---|---|
stayZones |
String | 'A' | optional, active zones (A,B,C) in 'Stay' mode |
nightZones |
String | 'B' | optional, active zones (A,B,C) in 'Night' mode |
occupancySensor |
Boolean | false | optional, add an occupancy widget linked to the alarm |
| WindowCovering parameters | Type | Default | Note |
|---|---|---|---|
defaultPosition |
Integer | 0 | optional, final position for UpDown rollershutter after any command |
reverse |
Boolean | false | optional, reverse up/down in case of bad mounting |
lowSpeed |
Boolean / String | false | optional, use low speed for roller shutter supporting it. If string, specify slot time with format "HH:MM-HH:MM". Low speed will be enabled between them. |
blindMode |
String | null | optional, change main slider action to orientation. By default, both closure and orientation will be set. When setting blindMode: true the blinds work in the following way: Opening the blinds or setting them to 100% will fully open them. Closing the blinds or setting them to 0% will fully close them. Setting the blinds to a value between 1% and 99% will first close the blinds and then adjust thier horizontal tilt in a way that 99% means fully horizonal = more light, and 1% means nearly closed = less light. |
blindsOnRollerShutter |
Boolean | false | optional, when blinds are installed on roller shutter motors allow slats to stay horizontal (opened) at intermediate position |
movementDuration |
Integer | 0 | optional, duration of a full shutter movement from 'open' to 'close' in seconds. Will be used to approximate shutter intermediate position. (0 = disable feature) |
| GarageDoorOpener parameters | Type | Default | Note |
|---|---|---|---|
cyclic |
Boolean | false | optional, restore closed state after cycleDuration seconds for stateless devices with cyclic behaviour |
cycleDuration |
Integer | false | optional, cycle duration (in seconds) for cyclic mode (default: 5 sec) |
reverse |
Boolean | false | optional, reverse up/down in case of bad mounting |
pedestrianDuration |
Integer | 0 | optional, duration for pedestrian position for RTS gates |
| HeatingSystem parameters | Type | Default | Note |
|---|---|---|---|
derogationDuration |
Integer | 1 | optional, duration (in hours) for derogation orders |
comfort |
Integer | 19 | optional, comfort temperature used as display for heaters controled by pilot wire |
eco |
Integer | 17 | optional, comfort temperature used as display for heaters controled by pilot wire |
Full configuration example:
{
"bridge": {
...
},
"description": "...",
"accessories": [],
"platforms":[
{
"platform": "Tahoma",
"name": "My Tahoma Bridge",
"user": "user@me.com",
"password": "MyPassw0rd",
"service": "somfy_europe",
"exclude": ["hue", "rts", "Main door", "Main door", "PositionableHorizontalAwning"],
"devicesConfig": [
{
"key": "Alarm",
"stayZones": "A,C"
},
{
"key": "Bedroom blind",
"blindMode": true
},
{
"key": "GarageDoor",
"reverse": true
},
{
"key": "UpDownRollerShutter",
"defaultPosition": 50
}
]
}
]
}
You are welcome to contribute to this plugin development by opening an issue in case of unexpected behaviour or unsupported device.