Skip to content

Latest commit

 

History

History
136 lines (109 loc) · 6.94 KB

potentials.md

File metadata and controls

136 lines (109 loc) · 6.94 KB

Define steering potentials

A steering potential is an instance of a Potential subclass. It implements prepare(system) for system-specific data and __call__(coords_angstrom, *, t) to return an "energy" for each structure. Steering tries to produce samples with lower energy. Choose potentials to describe the properties you want to favour, then pass the instances to a sampler. See the steering guide for information about the available steered sampling algorithms.

Choose from the available potentials

The following potentials are defined in bioemu2.denoising.steering.potentials. Many are copied and adapted from Boltz's potentials.py.

Potential What it penalises
BondLengthPotential Bond lengths outside reference bounds
BondAnglePotential Bond angles outside reference bounds
InterChainVDWOverlapPotential Van der Waals overlaps between atoms in different chains, excluding atom pairs at most three covalent bonds apart through a declared inter-chain bond
IntraChainVDWOverlapPotential Van der Waals overlaps within polymer chains, excluding pairs at most three covalent bonds apart
PolymerLocalClashPotential Short-range inter-residue clashes for pairs two or three covalent bonds apart, within polymer chains or across declared bonds
SymmetricChainCOMPotential Centres of mass of equivalent chains getting too close
PoseBustersPotential Violations of ligand distance bounds derived from bonds, angles, and non-bonded contacts
ChiralAtomPotential Incorrect chirality at ligand stereocentres
StereoBondPotential Incorrect ligand bond stereochemistry
PlanarBondPotential Non-planar ligand bonds that should be planar

These ten potentials form the default physicality potentials used by GuidedFKSampler and FKCSampler. Other potentials can describe structural properties for different purposes, such as favouring a particular protein conformation.

The module also provides two more specialised potentials: ContactPotential penalises atom pairs exceeding a contact distance, and TemplateReferencePotential penalises deviations from a rigid-aligned reference template.

Improve physicality with the default physicality potentials

GuidedFKSampler() and FKCSampler() both use the default physicality potentials, as do the CLI's --sampler edm_gd, edm_fk, and edm_fkc options. Start with edm_gd for gradient-based steering without particle resampling.

These potentials discourage clashes, broken bonds, and other geometry problems during generation. They do not guarantee that every sample will pass physicality checks or that its overall conformation is more accurate. The physicality filter only removes invalid structures; it does not repair them. Steering is especially useful for large structures, where few unsteered samples may pass the checks.

Select potentials to apply

The default physicality potentials are defined in get_default_potentials(). You can use a different set of potentials instead of the default physicality potentials.

In Python, construct the potentials you want and pass them to the sampler as potentials=[...]. This replaces the defaults; it does not add to them. See the Python example.

On the CLI, pass --potentials my.yaml. In that file, _target_ names the potential class and the remaining fields supply its constructor arguments:

potentials:
  - _target_: bioemu2.denoising.steering.potentials.BondLengthPotential
    sigma_tolerance: 10.0
    parameters: {guidance_weight: 0.05, resampling_weight: 0.1}

This file also replaces the default set, so the example applies only a bond-length restraint.

See potentials.py for descriptions, settings, and parameters of the predefined potentials.

Configure strength and schedules

For GuidedFKSampler, use each potential's parameters mapping to control its influence, as in the example above:

Parameter Effect
guidance_weight Scales the potential's coordinate gradient during guidance
guidance_interval Applies that gradient every N inner steps
resampling_weight Scales the potential's contribution to reweighting/resampling

Scheduled parameter values can change as denoising progresses. Use a ParameterSchedule such as PiecewiseStepFunction, ExponentialInterpolation, or LinearInterpolation. Normalised potential time runs from t=1 at high noise to t=0 at the clean endpoint. See the potential and schedule docstrings for supported parameters, units, and schedule arguments.

FKCSampler uses the returned energies directly; it does not use guidance_weight, guidance_interval, or resampling_weight. To change a potential's strength for FKC, scale its returned energy. Potential-specific parameters, such as a clash buffer, still determine that energy.

Write your own potential

Define a subclass of Potential with prepare(system) to set up system-specific data and __call__(coords_angstrom, *, t) to return one energy per structure. The sampling API calls prepare() for you. When evaluating a potential directly outside a sampler, call prepare(system) first and again when changing systems. The Potential API docstrings specify coordinate units, tensor shapes, and padding.

For guidance (gradient-based steering), the energy must be differentiable with respect to the coordinates. Keep its calculation in PyTorch without detaching the coordinates. Resampling-only steering needs energy values but not gradients. See choose a sampler for which sampler configurations use guidance.

Note

Each denoising step randomly rotates and translates the coordinates. A potential that changes under these transformations can give unintended results. Define potentials using rotation- and translation-invariant quantities, such as distances, rather than absolute positions. For example, a potential that compares coordinates with a fixed reference without first rigidly aligning them, or rewards elongation along a fixed global axis, changes when the sampler rotates or translates the structure.

For a complete custom potential, see TerminiTargetExpPotential in the chignolin example. It caches the terminal C-alpha indices and returns a quadratic penalty on their separation. See sample with steering for how to pass a potential to a sampler.